GENERAL
Monitor Performance Specifications |
| Display |
10.4" color TFT screen (800 x 600)
|
| Dimension |
270 (w) x 310 (h) x 172 (d) mm.
Approx. 4 kg (8.8 Lbs.)
|
| Trace |
5 waveforms (ECG, SpO2, 2 IBP, RR or EtCO2) |
| Sweep Speed |
6.25, 12.5, 25, 50 mm/sec |
| Indicators |
Categorized alarms (3 priority levels)
Visual alarm lamp handle
QRS Beep and alarm sound
Battery status
External power LED
|
| Interfaces |
LAN digital output for transferring data
VGA Out
Defib Sync Output
- Signal Level: 0 to 5 V pulse
- Pulse Width: 100 +/- 10ms
AC input : 100 ~ 240V, 50/60 Hz, 1.2A
DC input : 12 to 18Vdc, 2.5A Max.
DC output : 3.3Vdc, 700mA Max.
|
| Battery |
Internal battery: Li-ion
Battery status indicator
Operating Time: 2.5 hours typically (fully charged battery)
|
Thermal Printer
(Optional) |
Built-in, 3 channels
Speeds: 25, 50 mm/sec
Paper width: 58 mm
|
| Graphical and Tabular Trends |
| Tabular Trends |
Memory Storage: 24 hours
Data Interval: 1, 5, 15, 30 min., and 1 hour
Tabular Format: One table for all variables
|
| Graphical Trends |
Display duration: 30, 60, 90 min., 3, 6, 12 hours |
| Accessory |
| Standard Accessory |
3- lead ECG cable and clips - 1 ea.
Electrodes - 10 ea.
NIBP extension tube - 1 ea.
NIBP Neonate Cuff #1~#5 - 1 ea.
SpO2 sensor extension cable - 1 ea.
SpO2 sensor - 1 ea.
EtCO2 FilterLine set - 1 ea.
Power Transformer (DC Adaptor) - 1 ea.
pwoer Cable - 1 ea.
|
| Optional Accessory |
Temperature probe Surface/Skin, reusable
Thermal paper
5-lead patient cable
IBP disposable preasure transducer kit
IBP logic pressure transducer kit
|
PERFORMANCE
ECG |
| Leads |
3 leads or 5 leads selectable |
| Heart Rate Range |
30 to 300 bpm |
| Hearth Rate Accuracy |
+/- 3 bpm |
| Bandwidth |
0.5 Hz to 40 Hz |
| Sweep Speeds |
6.25, 12.5, 25, 50 mm/sec |
| ECG Size Sensitivity |
0.5, 1, 2, 4 mV/cm |
| Pacemaker Detection Mode |
Indicator on waveform display, user selectable |
| Differential Input Impedance |
>5MQ |
| CMRR |
>90dB at 50 or 60 Hz |
| Input Dynamic Range |
+/- 5mVAC, +/- 300 mVDC |
| Defibrillator Discharge |
< 4 sec |
| Arrhythmia analysis |
VTAC/VFIB, VTAC, ASYSTOLIC |
| Lead-Off Detection with display indicator |
| SpO2 |
|
| % Saturation Range |
0% to 100% |
| Pulse Rate |
30 to 254 bpm |
| SpO2 Accuracy |
- 70% to 100% +/- 2 digits
- 0% to 69% unspecified |
| NIBP |
| Method |
Oscillometric |
| Measurement Modes |
Manual, Automatic, STAT |
| Cuff Pressure Display |
0 to 300mmHg in 1mmHg step |
| B.P. measurement range |
Systolic: 50 to 270 mmHg
Mean Arterial Pressure: 40 to 245 mmHg
Diastolic: 30 to 220 mmHg |
| Over pressure protection |
Yes |
| Adjustable Cuff Inflation Pressure |
| Respirations |
| Range |
5 to 120 breaths/min |
| Accuracy |
+/- 3 breaths/min |
| Sweep Speeds |
6.25, 12.5, 25, 50 mm/sec |
| Apnea alarm |
0 to 30 sec |
| Temperature Unit |
| Range |
15° C to 45° C (59° F to 113° F) |
| Accuracy |
- 25°C to 45° C +/- 0.1°C
- 15°C to 24°C +/- 0.2°C |
| Compatible with |
YS1 Series 400 temperature probes |
| IBP |
| Channels |
2 |
| Measuring Range |
-50 to 300 mmHg |
| Measuring Accuracy |
+/- 1 mmHg +/- 1 digit (<100 mmHg)
+/- 1 % +/- 1 digit (>100 mmHg) |
| Pulse rate counting range |
0 to 300 beats/min |
| Zero balancing range |
+/- 200 mmHg |
| Accuracy |
+/- 1 mmHg |
| Drift |
+/- 1 mmHg over 24 hours |
| Transducer sensitivity |
5_v/V/mmHg |
| EtCO2 |
| Method |
Infrared Absorption |
| Measurement Mode |
MicroStream |
| Measurement Range |
0 to 99 mmHg |
| Respiration Range |
0 to 150 bpm |
| Accuracy |
+/- 2 mmHg, 0 to 40 mmHg
+/- 5 mmHg, 41 to 76 mmHg
+/- 10 mmHg, 77 to 99 mmHg |
| Resolution |
1mmHg |
| Apnea alarm |
Yes |