Elite Performance
BM7Vet Pro
The new BM7Vet Pro boasts optional EtCO2, anesthetic gas modules and a Dual Gas module, in addition to standard ECG, Respiration, NIBP and SpO2. Its 12.1” wide color monitor displays all the vital signs that you want in different colors. A standard built-in printer offers documentation of all measured and numeric values, as well as up to 6 waveforms. Alarms and settings are easily adjustable and are retained after turning off the power. Wi-Fi capability now come standard with the BM7Vet Pro.
FEATURES
- ECG, SpO2, NIBP, Respiration and 2 Temperatures
- 2 IBP (Optional)
- Mainstream/Sidestream EtCO2 (Optional)
- Mainstream/Sidestream Anesthetic Gas/O2 (Optional)
- Bionet Dual Gas (Optional)
- ST Level, PVC Count Real-Time Display
- 13 Kinds of Arrhythmia Analysis
- 12.1″ Color TFT Touch Screen with 6 Wave Forms (1024 X 768 pixels)
- Individual Sweep-Speed Setting for Each Parameter
- Multiple Display Modes
- Remembers Your Settings
- 168 Full Hours of Trend Data Are Stored
- 48 Hours of Full Disclosure Waveforms Provided
- USB Memory Storage
- 2 USB Port
- SD Card Slot
- BT-Link Pro and BT-Link Mobile for Real-Time Monitoring and Data Recording
- B2B (Bed to Bed), Up to 8 BM7Vet Pro Can Be Controlled
- External HDMI Output for Large Screen
- Li-ion Rechargeable Battery Allows Cordless Use for Up To 4 Hours
- Industry’s Longest Warranty – 4 Years
The new BM7Vet Pro boasts optional EtCO2, anesthetic gas modules and a Dual Gas module, in addition to standard ECG, Respiration, NIBP and SpO2. Its 12.1” wide color monitor displays all the vital signs that you want in different colors. A standard built-in printer offers documentation of all measured and numeric values, as well as up to 6 waveforms. Alarms and settings are easily adjustable and are retained after turning off the power. Wi-Fi capability now come standard with the BM7Vet Pro.
Intended Use: To monitor vital signs in veterinary patients (feline, canine), including: ECG, SpO2, NIBP, IBP, Respiration, and Temperature. (Option: EtCO2, Dual Gas, and Anesthetic Gas/O2)
Superior Advantages
- ECG, SpO2, NIBP, Respiration, and 2 Temperature (Option: 2 IBP, EtCO2, Dual Gas, and Anesthetic Gas/O2)
- 12.1″ color TFT touch screen with 6 wave forms (1024 X 768 pixels)
- Individual sweep speed setting for each parameter
- Remembers your settings
- Multiple display modes available
- Screen Freeze ON/OFF
Enhanced & Extendible Multi-Parameters (Option)
- Mainstream/Sidestream EtCO2
- Mainstream/Sidestream Anesthetic Gas/O2
- Bionet Dual Gas (EtCO2 and anesthetic gas monitoring)
Enhanced Data Management
- 168 full hours of trend data can be stored
- Easy network connectivity, supports wireless LAN
- Automatic Search for available Wi-Fi networks
- B2B, Up to 8 BM7Vet Pro patient monitors can be controlled by one of the networked BM Vet Pro series
- BT-Link Pro and BT-Link Mobile for real-time monitoring and recording
- USB memory storage
High-Performance Measurement
- 48 hours of full disclosure waveforms provided
- ST level, PVC count real-time display
- 13 kinds of arrhythmia analysis
Transportable
- Li-ion rechargeable battery with longer lifetime (Up to 2hrs for continuous operation / 4hrs using optional battery)
- External HDMI output for large screen
- 2 USB Port
- SD Card Slot
Industry’s longest warranty – 4-YEAR WARRANTY (6 months on accessories)
Includes:
BM7Vet Pro Main Unit, Temperature Probe (Esophageal/Rectal), SpO2 Probe (Transflectance), Esophageal Probe with 3-lead ECG and Temperature – Medium Size, Extension cable for esophageal probe, 3 Lead Vet ECG Cable (alligator type), SpO2 Probe (Y-Clip) and Extension Cable, NIBP Vet Infant Cuff, NIBP Vet Neonate Cuffs (#1 – #5), NIBP Extension Hose, Chart Paper (X2), USB WiFi dongle, Power Adaptor & Power Cord, Operation Manual, BT-Link Pro Software, and 4-Year Warranty Card.
Options:
Dual Gas Module By Bionet, CAPNOSTAT 5 Mainstream EtCO2 Sensor By Respironics® & Airway Adapters, LoFlo Sidestream EtCO2 Sensor By Respironics® & Airway Adapters, 5 Lead All In One ECG Cable, 3 Lead ECG Cable (snap type), ECG Alligator Clip, Temperature Probe (skin), and IBP Accessories.
Caution: Federal law restricts this device to sale by or on the order of a licensed veterinarian.
General
wdt_ID | Feature | Specification |
---|---|---|
73 | Display, Resolution | 12.1' Wide color TFT LCD, (1024 x 768 pixels) |
74 | Dimension, Weight | 322 (W) x 250 (H) x 224.8 (D) mm, Approx. 4.5 kg |
75 | Trace | 6 waveforms: 2*ECG, SpO2, RR or EtCO2 or MGAS, 2*IBP Sweep speed : 6.25, 12.5, 25, 50 mm/sec |
77 | Indicators | Categorized alarms (3 priority levels) Visual alarm lamp handle QRS beep & SpO2 pulse beep Percent(%) SpO2 pitch tone Battery status, external power LED Touch screen, rotary knob |
78 | Interfaces | Power supply: AC 100 - 240V (50/60Hz) DC input connector : 18VDC, 2.8A LAN digital output for transferring data Nurse call system connection -0.3A at 125 VAC -1A at 24 VDC External HDMI monitor connection USB barcode reader USB memory data storage / Software Upgrade |
79 | Battery | Rechargeable Li-ion battery 2 hours for continuous operation (Option: Using additional battery total of 4 hours) |
80 | Thermal Printer (Optional) | Speed: 25, 50mm/sec paper width: 58mm |
82 | Data Storage | 168 hours trends, 20 cases of 10 sec alarm waveform |
83 | Language | English, French, Spanish, Italian, German, Chinese, Russian, Czech, Polish, Turkish, Romanian, Portuguese, Bulgarian, Hungarian, Korean, Japanese, Greek |
84 | Standard Accessories | 3 lead vet ECG cable - 1 ea NIBP extension hose (3m) - 1 ea NIBP vet cuff Neonate disposable #1 - #5 - 1 set NIBP vet cuff infant (reusable) - 1 ea SpO2 extension cable (2m) - 1 ea Esophageal ECG probe with temperature - 1 ea Extension cable for esophageal probe - 1 ea Transflectance SpO2 probe - 1 ea Temperature probe (rectal/esophageal) - 1 ea Reusable multisite SpO2 probe - 1 ea DC adapter (18 VDC, 2.5 A) - 1 set BT-Link Pro automated record keeping software - 1 ea |
Performance
wdt_ID | ECG | Specification |
---|---|---|
88 | Lead Type | 3-lead 5-lead (option) |
89 | Lead Selection | 3-lead: I, II, III 5-lead (option): I, II, III, aVR, aVL, aVF, V |
91 | ECG Waveforms | 3-lead: 1 channel 5-lead (option): 1/2/7 channels |
93 | Heart Rate Range | Horse, Dog: 30 - 300 BPM Puppy, Cat: 30 - 350 BPM |
94 | Heart Rate Accuracy | ± 1 BPM or ± 1%, whichever is greater |
95 | Sweep Speed | 6.25, 12.5, 25, 50 mm/sec |
96 | Filter | Diagnosis: 0.05 ~ 150 Hz Monitoring: 0.5 ~ 40 Hz Moderate: 0.5 ~ 25 Hz Maximum: 5 ~ 25 Hz |
97 | S-T Segment Detection Range | -2.0 to 2.0 mV |
98 | Arrhythmia Analysis | ASYSTOLE, VTACH, V-FIB, BIGEMINY, ACCVENT, COUPLET, IRREGULAR, PAUSE, PVC, RONT, TRIGMINY, VBRADY, SHORTRUN |
99 | Protection | Against electrosurgical interference and defibrillation |
wdt_ID | Respiration | Specification |
---|---|---|
100 | Method | Thoracic impedance |
101 | Channel Selection | RA-LA or RA-LL |
102 | Measurement Range | 5 - 120 breath per minute |
103 | Accuracy | ±1 breath per minute |
104 | Apnea Alarm | Yes |
wdt_ID | SpO2 | Specification |
---|---|---|
105 | Saturation Range | 0 to 100 % |
106 | Saturation Accuracy | 70 to 100% ±2 digits, 0 to 69% unspecified |
107 | Pulse Rate Range | 30 to 254 BPM |
108 | Pulse Rate Accuracy | ±2 BPM |
wdt_ID | NIBP - Suntech | Specification |
---|---|---|
110 | Method | Oscillometric |
111 | Operation Mode | Manual / Automatic / Continuous |
112 | Pressure Range | 0 to 300mmHg (accuracy : ±3mmHg) |
113 | Measurement Range | Sytolic: 40 – 265mmHg MAP: 27 – 222mmHg Diastolic: 20 – 200mmHg |
114 | Initial Inflation Pressure | Large animal mode: 160mmHg (default), Variable from 120 - 280mmHg Small animal mode: 160mmHg (default), Variable from 60 - 280mmHg |
115 | Pulse Rate Range | 25-300 BPM (Beat Per Minute) |
wdt_ID | Temperature | Specification |
---|---|---|
117 | Channels | 2 |
118 | Measurement Range | 0 to 50°C (32°F to 122°F) |
119 | Accuracy | 25 to 50°C: ±0.1°C 0 to 24°C: ±0.2°C |
120 | Compatibility | YS1 Series 400 temperature probes |
wdt_ID | IBP (Option) | Specification |
---|---|---|
126 | Channels | 2 |
127 | Measurement Range | -50 to 300 mmHg |
128 | Accuracy | less than 100 mmHg: ± 1 mmHg equal or greater than 100 mmHg: ± 1% of reading |
129 | Pulse Rate Range | 0 to 300 BPM |
130 | Zero Balancing Range | Range: ± 200 mmHg Accuracy: ± 1 mmHg Drift: ± 1 mmHg over 24 hours |
131 | Transducer Sensitivity | 5μV/V/mmHg |
wdt_ID | Mainstream EtCO2 - Respironics (Option) | Specification |
---|---|---|
126 | Measurement Range | 0 to 150 mmHg, 0 to 19% |
127 | Accuracy | 0 - 40 mmHg ± 2 mmHg 41 - 70 mmHg ± 5% of reading 71 - 100 mmHg ± 8% of reading 101 - 150 mmHg ± 10% of reading |
128 | Respiration Rate | 0 to 150 breaths per minute |
129 | Respiration Accuracy | ± 1 breath per minute |
wdt_ID | Sidestream EtCO2 - Respironics (Option) | Specification |
---|---|---|
121 | Measurement Range | 0 to 150 mmHg, 0 to 19% |
122 | Accuracy | 0 - 40 mmHg ± 2 mmHg 41 - 70 mmHg ± 5% of reading 71 - 100 mmHg ± 8% of reading 101 - 150 mmHg ± 10% of reading |
123 | Respiration Rate | 2 to 150 breaths per minute |
124 | Respiration Accuracy | ± 1 breath per minute |
wdt_ID | Dual Gas - Bionet (Option) | Specification |
---|---|---|
110 | Method | Sidestream |
111 | Gas | CO₂, Iso, Sev, Enf, Hal, Des |
112 | Range, Accuracy | CO₂: 0-10%, ± (0.2 vol% + 4% relative) Iso/Sev/Enf/Hal: 0-6%, ± (0.15% vol% + 4% relative) Des: 0-18%, ± (0.15% vol% + 4% relative) |
113 | Respiration Rate | 0-150 BPM ±1 BPM |
wdt_ID | Anesthetic Gas / O₂ - Masimo (Option) | Specification |
---|---|---|
110 | Method | Infra-red absorption characteristic |
111 | Mainstream | IRMA AX+ |
112 | Sidestream | ISA OR+ / AX+ |
113 | Gas | CO₂, O₂, N₂O, Des, Iso, Enf, Hal, Sev |
114 | Warm-up Time | Mainstream (IRMA AX+) - Iso accuracy mode: 45s - Full accuracy mode: 60s Sidestream (ISA OR+/ AX+): |
115 | Sample Flow Rate(for ISA OR+ / AX+) | 50 ± 10ml/min |
116 | Measurement Range | CO₂: 0 ~ 15 % N₂O: 0 ~ 100% Hal/Iso/Enf: 0 ~ 8 % Sev: 0 ~ 10 % Des: 0 ~ 22 % O₂: 0 ~ 100% (ISA OR+) |
117 | Respiration Rate | 0 ~ 150 BPM ± 1 BPM |
* Specifications can be changed without prior notification.
* You may have distortion or signal noise when you use nonstandard or other brands’ accessories. We strongly recommend you use only the authorized accessories which we supply.
* The ST algorithm has been tested for accuracy of the ST segment data. The significance of the ST segment changes needs to be determined by a veterinarian.
BIONET BM VET PRO Veterinary Multi-Parameter Monitor – Introduction and Walkthrough
How to connect BT-Link Pro to Bionet Veterinary Monitor
Bionet BT-Link Pro Software Overview
How to use BT-Link Pro Software
How to use BT-Link Mobile for Android
How to use BT-Link Mobile for iOS
Bionet BT-Link Mobile – Server vs Client Mode
wdt_ID | Item | Type | Download |
---|---|---|---|
1 | Leaflet | Download | |
2 | User Manual | Download | |
3 | Bionet BM Pro Series Accessory List | Download | |
4 | NIBP Guideline | Download | |
6 | SunTech Advantage VET Paper | Download | |
8 | Bionet Veterinary Monitor Power and Battery Guide | Download | |
9 | Bionet Veterinary Monitor BM Pro Series Quick Guide | Download | |
10 | Bionet Dual Gas Module Quick Guide | Download | |
11 | Quick Reference Guide for Networking the BIONET BM PRO Series | Download |
- Overview
-
The new BM7Vet Pro boasts optional EtCO2, anesthetic gas modules and a Dual Gas module, in addition to standard ECG, Respiration, NIBP and SpO2. Its 12.1” wide color monitor displays all the vital signs that you want in different colors. A standard built-in printer offers documentation of all measured and numeric values, as well as up to 6 waveforms. Alarms and settings are easily adjustable and are retained after turning off the power. Wi-Fi capability now come standard with the BM7Vet Pro.
Intended Use: To monitor vital signs in veterinary patients (feline, canine), including: ECG, SpO2, NIBP, IBP, Respiration, and Temperature. (Option: EtCO2, Dual Gas, and Anesthetic Gas/O2)
Superior Advantages
- ECG, SpO2, NIBP, Respiration, and 2 Temperature (Option: 2 IBP, EtCO2, Dual Gas, and Anesthetic Gas/O2)
- 12.1″ color TFT touch screen with 6 wave forms (1024 X 768 pixels)
- Individual sweep speed setting for each parameter
- Remembers your settings
- Multiple display modes available
- Screen Freeze ON/OFF
Enhanced & Extendible Multi-Parameters (Option)
- Mainstream/Sidestream EtCO2
- Mainstream/Sidestream Anesthetic Gas/O2
- Bionet Dual Gas (EtCO2 and anesthetic gas monitoring)
Enhanced Data Management
- 168 full hours of trend data can be stored
- Easy network connectivity, supports wireless LAN
- Automatic Search for available Wi-Fi networks
- B2B, Up to 8 BM7Vet Pro patient monitors can be controlled by one of the networked BM Vet Pro series
- BT-Link Pro and BT-Link Mobile for real-time monitoring and recording
- USB memory storage
High-Performance Measurement
- 48 hours of full disclosure waveforms provided
- ST level, PVC count real-time display
- 13 kinds of arrhythmia analysis
Transportable
- Li-ion rechargeable battery with longer lifetime (Up to 2hrs for continuous operation / 4hrs using optional battery)
- External HDMI output for large screen
- 2 USB Port
- SD Card Slot
Industry’s longest warranty – 4-YEAR WARRANTY (6 months on accessories)
Includes:
BM7Vet Pro Main Unit, Temperature Probe (Esophageal/Rectal), SpO2 Probe (Transflectance), Esophageal Probe with 3-lead ECG and Temperature – Medium Size, Extension cable for esophageal probe, 3 Lead Vet ECG Cable (alligator type), SpO2 Probe (Y-Clip) and Extension Cable, NIBP Vet Infant Cuff, NIBP Vet Neonate Cuffs (#1 – #5), NIBP Extension Hose, Chart Paper (X2), USB WiFi dongle, Power Adaptor & Power Cord, Operation Manual, BT-Link Pro Software, and 4-Year Warranty Card.Options:
Dual Gas Module By Bionet, CAPNOSTAT 5 Mainstream EtCO2 Sensor By Respironics® & Airway Adapters, LoFlo Sidestream EtCO2 Sensor By Respironics® & Airway Adapters, 5 Lead All In One ECG Cable, 3 Lead ECG Cable (snap type), ECG Alligator Clip, Temperature Probe (skin), and IBP Accessories.Caution: Federal law restricts this device to sale by or on the order of a licensed veterinarian.
- Specifications
-
General
wdt_ID Feature Specification 73 Display, Resolution 12.1' Wide color TFT LCD, (1024 x 768 pixels) 74 Dimension, Weight 322 (W) x 250 (H) x 224.8 (D) mm, Approx. 4.5 kg 75 Trace 6 waveforms: 2*ECG, SpO2, RR or EtCO2 or MGAS, 2*IBP
Sweep speed : 6.25, 12.5, 25, 50 mm/sec77 Indicators Categorized alarms (3 priority levels)
Visual alarm lamp handle
QRS beep & SpO2 pulse beep
Percent(%) SpO2 pitch tone
Battery status, external power LED
Touch screen, rotary knob78 Interfaces Power supply: AC 100 - 240V (50/60Hz)
DC input connector : 18VDC, 2.8A
LAN digital output for transferring data
Nurse call system connection
-0.3A at 125 VAC
-1A at 24 VDC
External HDMI monitor connection
USB barcode reader
USB memory data storage / Software Upgrade79 Battery Rechargeable Li-ion battery
2 hours for continuous operation
(Option: Using additional battery total of 4 hours)80 Thermal Printer (Optional) Speed: 25, 50mm/sec
paper width: 58mm82 Data Storage 168 hours trends, 20 cases of 10 sec alarm waveform 83 Language English, French, Spanish, Italian, German, Chinese, Russian, Czech, Polish, Turkish, Romanian, Portuguese, Bulgarian, Hungarian, Korean, Japanese, Greek 84 Standard Accessories 3 lead vet ECG cable - 1 ea
NIBP extension hose (3m) - 1 ea
NIBP vet cuff Neonate disposable #1 - #5 - 1 set
NIBP vet cuff infant (reusable) - 1 ea
SpO2 extension cable (2m) - 1 ea
Esophageal ECG probe with temperature - 1 ea
Extension cable for esophageal probe - 1 ea
Transflectance SpO2 probe - 1 ea
Temperature probe (rectal/esophageal) - 1 ea
Reusable multisite SpO2 probe - 1 ea
DC adapter (18 VDC, 2.5 A) - 1 set
BT-Link Pro automated record keeping software - 1 eaPerformance
wdt_ID ECG Specification 88 Lead Type 3-lead
5-lead (option)89 Lead Selection 3-lead: I, II, III
5-lead (option): I, II, III, aVR, aVL, aVF, V91 ECG Waveforms 3-lead: 1 channel
5-lead (option): 1/2/7 channels93 Heart Rate Range Horse, Dog: 30 - 300 BPM
Puppy, Cat: 30 - 350 BPM94 Heart Rate Accuracy ± 1 BPM or ± 1%, whichever is greater 95 Sweep Speed 6.25, 12.5, 25, 50 mm/sec 96 Filter Diagnosis: 0.05 ~ 150 Hz
Monitoring: 0.5 ~ 40 Hz
Moderate: 0.5 ~ 25 Hz
Maximum: 5 ~ 25 Hz97 S-T Segment Detection Range -2.0 to 2.0 mV 98 Arrhythmia Analysis ASYSTOLE, VTACH, V-FIB, BIGEMINY, ACCVENT, COUPLET, IRREGULAR, PAUSE, PVC, RONT, TRIGMINY, VBRADY, SHORTRUN 99 Protection Against electrosurgical interference and defibrillation
wdt_ID Respiration Specification 100 Method Thoracic impedance 101 Channel Selection RA-LA or RA-LL 102 Measurement Range 5 - 120 breath per minute 103 Accuracy ±1 breath per minute 104 Apnea Alarm Yes
wdt_ID SpO2 Specification 105 Saturation Range 0 to 100 % 106 Saturation Accuracy 70 to 100% ±2 digits, 0 to 69% unspecified 107 Pulse Rate Range 30 to 254 BPM 108 Pulse Rate Accuracy ±2 BPM
wdt_ID NIBP - Suntech Specification 110 Method Oscillometric 111 Operation Mode Manual / Automatic / Continuous 112 Pressure Range 0 to 300mmHg (accuracy : ±3mmHg) 113 Measurement Range Sytolic: 40 – 265mmHg
MAP: 27 – 222mmHg
Diastolic: 20 – 200mmHg114 Initial Inflation Pressure Large animal mode: 160mmHg (default), Variable from 120 - 280mmHg
Small animal mode: 160mmHg (default), Variable from 60 - 280mmHg115 Pulse Rate Range 25-300 BPM (Beat Per Minute)
wdt_ID Temperature Specification 117 Channels 2 118 Measurement Range 0 to 50°C (32°F to 122°F) 119 Accuracy 25 to 50°C: ±0.1°C
0 to 24°C: ±0.2°C120 Compatibility YS1 Series 400 temperature probes
wdt_ID IBP (Option) Specification 126 Channels 2 127 Measurement Range -50 to 300 mmHg 128 Accuracy less than 100 mmHg: ± 1 mmHg
equal or greater than 100 mmHg: ± 1% of reading129 Pulse Rate Range 0 to 300 BPM 130 Zero Balancing Range Range: ± 200 mmHg
Accuracy: ± 1 mmHg
Drift: ± 1 mmHg over 24 hours131 Transducer Sensitivity 5μV/V/mmHg
wdt_ID Mainstream EtCO2 - Respironics (Option) Specification 126 Measurement Range 0 to 150 mmHg, 0 to 19% 127 Accuracy 0 - 40 mmHg ± 2 mmHg
41 - 70 mmHg ± 5% of reading
71 - 100 mmHg ± 8% of reading
101 - 150 mmHg ± 10% of reading128 Respiration Rate 0 to 150 breaths per minute 129 Respiration Accuracy ± 1 breath per minute
wdt_ID Sidestream EtCO2 - Respironics (Option) Specification 121 Measurement Range 0 to 150 mmHg, 0 to 19% 122 Accuracy 0 - 40 mmHg ± 2 mmHg
41 - 70 mmHg ± 5% of reading
71 - 100 mmHg ± 8% of reading
101 - 150 mmHg ± 10% of reading123 Respiration Rate 2 to 150 breaths per minute 124 Respiration Accuracy ± 1 breath per minute
wdt_ID Dual Gas - Bionet (Option) Specification 110 Method Sidestream 111 Gas CO₂, Iso, Sev, Enf, Hal, Des 112 Range, Accuracy CO₂: 0-10%, ± (0.2 vol% + 4% relative)
Iso/Sev/Enf/Hal: 0-6%, ± (0.15% vol% + 4% relative)
Des: 0-18%, ± (0.15% vol% + 4% relative)113 Respiration Rate 0-150 BPM ±1 BPM wdt_ID Anesthetic Gas / O₂ - Masimo (Option) Specification 110 Method Infra-red absorption characteristic 111 Mainstream IRMA AX+ 112 Sidestream ISA OR+ / AX+ 113 Gas CO₂, O₂, N₂O, Des, Iso, Enf, Hal, Sev 114 Warm-up Time Mainstream (IRMA AX+)
- Iso accuracy mode: 45s
- Full accuracy mode: 60s
Sidestream (ISA OR+/ AX+):115 Sample Flow Rate(for ISA OR+ / AX+) 50 ± 10ml/min 116 Measurement Range CO₂: 0 ~ 15 %
N₂O: 0 ~ 100%
Hal/Iso/Enf: 0 ~ 8 %
Sev: 0 ~ 10 %
Des: 0 ~ 22 %
O₂: 0 ~ 100% (ISA OR+)117 Respiration Rate 0 ~ 150 BPM ± 1 BPM * Specifications can be changed without prior notification.
* You may have distortion or signal noise when you use nonstandard or other brands’ accessories. We strongly recommend you use only the authorized accessories which we supply.
* The ST algorithm has been tested for accuracy of the ST segment data. The significance of the ST segment changes needs to be determined by a veterinarian. - Accessories
-
- Videos
-
BIONET BM VET PRO Veterinary Multi-Parameter Monitor – Introduction and Walkthrough
How to connect BT-Link Pro to Bionet Veterinary Monitor
Bionet BT-Link Pro Software Overview
How to use BT-Link Pro Software
How to use BT-Link Mobile for Android
How to use BT-Link Mobile for iOS
Bionet BT-Link Mobile – Server vs Client Mode
- Downloads
-
wdt_ID Item Type Download 1 Leaflet Download 2 User Manual Download 3 Bionet BM Pro Series Accessory List Download 4 NIBP Guideline Download 6 SunTech Advantage VET Paper Download 8 Bionet Veterinary Monitor Power and Battery Guide Download 9 Bionet Veterinary Monitor BM Pro Series Quick Guide Download 10 Bionet Dual Gas Module Quick Guide Download 11 Quick Reference Guide for Networking the BIONET BM PRO Series Download