Spirometer - Pulmonary Function Testing - Touch Screen
SpiroCare
The SpiroCare unit is an accurate and hygienic spirometer. It features 7” color touch screen, provides FVC/SVC/MVV/post-bronchodilator tests, candle blowing-out animation to encourage patient success, accurate measurement from disposable mouthpiece with patented-sensor method, prints PFT test report with interpretation, and a 3-year warranty.
Saves up to 200 tests internally and exports saved data to USB flash drive, in JPEG/PDF/DCM file formats.
FEATURES
- FVC, SVC, and MVV Test
- PFT Test Report with Interpretation
- Pre- and Post-Bronchodilator Comparison
- 7” Color Touch Screen
- WiFi Support
- Built-In Printer and Rechargeable Battery
- Disposable Mouthpiece with Patented Sensing Method
- 3-Year Warranty
- Built-In Memory and Supports USB Flash Drive
- A4 Full-Size Paper
or |
BUY NOW |
It is highly recommended to calibrate a spirometer with Bionet 3L calibration syringe periodically, in order to ensure accurate calibration of your spirometer.
Our calibration recommendations are based upon guidelines from the American Thoracic Society (ATS) and the European Respiratory Society (ERS)
- The volume accuracy of the spirometer must be checked at least daily with a single discharge of a 3-L calibrated syringe.
- At least quarterly, volume spirometers must have their calibration checked over their entire volume range using a calibrated syringe or an equivalent volume standard. The measured volume should be within 3.5% of the reading or 65 mL, whichever is greater. This limit includes the 0.5% accuracy limit for a 3-L syringe.
The SpiroCare unit is an accurate and hygienic spirometer. It features 7” color touch screen, provides FVC/SVC/MVV/post-bronchodilator tests, candle blowing-out animation to encourage patient success, accurate measurement from disposable mouthpiece with patented-sensor method, prints PFT test report with interpretation, and a 3-year warranty.
For data management, it saves up to 200 tests internally and exports saved data to USB flash drive, in JPEG/PDF/DCM file formats.
Performance
- FVC (Forced Vital Capacity), SVC (Slow Vital Capacity), and MVV (Maximum Voluntary Maximum) test.
- Pre- and post-bronchodilator comparison.
- Accurate measurement by using disposable mouthpiece with built-in sensor.
- PFT test report with interpretation.
User-Friendliness
- 7” color screen for displaying measurement in real time.
- Touch interface for easily entering patient information.
- Built-in printer and rechargeable battery.
- USB barcode reader and keyboard can be attached through USB ports.
- Disposable mouthpiece with patented sensing method is hygienic and eliminates the hassle of cleaning.
Data Management
- Saves up to 200 tests internally.
- Exports the saved data to USB flash drive as JPEG/PDF/DCM file format.
Special Advantage
- 3-year warranty
Includes:
SpiroCare Main Unit with Spirometer Handle, 1 Medi-Graph Paper Roll, 20 Disposable Mouthpieces, 1 Nose Clip, 1 Mouthpiece Adapter, Hospital Grade Power Cord, Operation Manual, Diagnostics Guide Book and 3-Year Warranty Card. WiFi USB Dongle and USB Flash Drive with BMS-Plus Software Included.
Option:
Cart
Bernoulli’s Law | Pneumotachometer | Turbine | |
Structure | ![]() |
![]() |
![]() |
Medium | Screen | Propeller or turbine | |
Accuracy |
Error ratio < 1% (equal air density) |
Error ratio < 5% (air friction) |
Error ratio < 20% (inertia problem) |
No air friction No cleaning or sterlization |
High probability of infection because of remain saliva or bacteria | High probability of infection because of remain saliva or bacteria and low accuracy |
wdt_ID | Feature | Specification |
---|---|---|
47 | Dimension | 296 (W) x 305.5 (H) x 34 (D) mm, approx. 250 kg |
48 | Measuring Values | - FVC: FVC, FEV 1.0, FEV 1/FVC, FEF 0.2-1.2l, fef 25-75%, FEF 75-85%, PEF, FEF 25%, FEF 50%, FEF 75%, FIVC, FEV6, PEFT, FET100%, Extrapolated Volume - SVC: SVC, ERV, IRV, TV, EC - MVV: MVV, FB, TV |
56 | Presentation | Flow volume loop MVV: MVV, FB, TV Measurement values table |
59 | Measuring Range | Flow: 0 to ± 14 L/s Volume: 0 to ± 12 L |
62 | Measuring Method | Differential pressure method |
65 | Prediction Equation | Morris-Polgar, ECCS-Quanjer, Knudson-ITS, Pereira, Korea CJK |
66 | Sample Rate | 200 samples/sec |
67 | Flow Impedance | < 0.2 mbar s/l at 12 l/s |
68 | Measuring Accuracy | Complies with ATS (American Thoracic Society) |
69 | Environment | Ambient temperature: 15 to 40°C (59 to 104°F) Relative humidity: 10 to 90% (non-condensing) Atmospheric pressure: 700 to 1060 hPa |
* Specifications can be changed without prior notification.
Item Code | Item Description | |||
---|---|---|---|---|
wdt_ID | Item Image | Item Code | Item Description | Buy Now |
63 | ![]() |
ECG-BAT-B | ECG rechargeable battery (Li-ion) for Cardio7 with serial number starting with T9 | Buy Now |
65 | ![]() |
USB-WIFI24 | USB WiFi dongle (2.4 GHz) | Buy Now |
66 | ![]() |
PC-A (H) | Hospital grade power cable | Buy Now |
67 | ![]() |
ECG-CART | ECG cart for CardioCare 2000 and Cardio7 (hanger not included, must be purchased separately) | Buy Now |
71 | ![]() |
ECG-STYLUS | ECG touch screen stylus pen (for Cardio7 only) | Buy Now |
72 | ![]() |
SPM-300(U) | Spirometer – requires Cardio7 ECG unit. Includes: one sensor, one handle dock, one nose clip, one diagnosis guide, one operation manual, and 100 mouthpieces – Does Not include calibration syringe. |
Contact Sales |
73 | ![]() |
SPM-MP | SmarTube (disposable mouthpiece - 100/box) (no warranty) | Buy Now |
74 | ![]() |
SPM-CS | 3L calibration syringe (90-day warranty) | Buy Now |
- Overview
-
It is highly recommended to calibrate a spirometer with Bionet 3L calibration syringe periodically, in order to ensure accurate calibration of your spirometer.
Our calibration recommendations are based upon guidelines from the American Thoracic Society (ATS) and the European Respiratory Society (ERS)
- The volume accuracy of the spirometer must be checked at least daily with a single discharge of a 3-L calibrated syringe.
- At least quarterly, volume spirometers must have their calibration checked over their entire volume range using a calibrated syringe or an equivalent volume standard. The measured volume should be within 3.5% of the reading or 65 mL, whichever is greater. This limit includes the 0.5% accuracy limit for a 3-L syringe.
The SpiroCare unit is an accurate and hygienic spirometer. It features 7” color touch screen, provides FVC/SVC/MVV/post-bronchodilator tests, candle blowing-out animation to encourage patient success, accurate measurement from disposable mouthpiece with patented-sensor method, prints PFT test report with interpretation, and a 3-year warranty.
For data management, it saves up to 200 tests internally and exports saved data to USB flash drive, in JPEG/PDF/DCM file formats.
Performance
- FVC (Forced Vital Capacity), SVC (Slow Vital Capacity), and MVV (Maximum Voluntary Maximum) test.
- Pre- and post-bronchodilator comparison.
- Accurate measurement by using disposable mouthpiece with built-in sensor.
- PFT test report with interpretation.
User-Friendliness
- 7” color screen for displaying measurement in real time.
- Touch interface for easily entering patient information.
- Built-in printer and rechargeable battery.
- USB barcode reader and keyboard can be attached through USB ports.
- Disposable mouthpiece with patented sensing method is hygienic and eliminates the hassle of cleaning.
Data Management
- Saves up to 200 tests internally.
- Exports the saved data to USB flash drive as JPEG/PDF/DCM file format.
Special Advantage
- 3-year warranty
Includes:
SpiroCare Main Unit with Spirometer Handle, 1 Medi-Graph Paper Roll, 20 Disposable Mouthpieces, 1 Nose Clip, 1 Mouthpiece Adapter, Hospital Grade Power Cord, Operation Manual, Diagnostics Guide Book and 3-Year Warranty Card. WiFi USB Dongle and USB Flash Drive with BMS-Plus Software Included.Option:
Cart - Specifications
-
Bernoulli’s Law Pneumotachometer Turbine Structure Medium Screen Propeller or turbine Accuracy Error ratio < 1%
(equal air density)
Error ratio < 5%
(air friction)
Error ratio < 20%
(inertia problem)
No air friction
No cleaning
or sterlizationHigh probability of infection because of remain saliva or bacteria High probability of infection because of remain saliva or bacteria and low accuracy wdt_ID Feature Specification 47 Dimension 296 (W) x 305.5 (H) x 34 (D) mm, approx. 250 kg 48 Measuring Values - FVC: FVC, FEV 1.0, FEV 1/FVC, FEF 0.2-1.2l, fef 25-75%, FEF 75-85%, PEF, FEF 25%, FEF 50%, FEF 75%, FIVC, FEV6, PEFT, FET100%, Extrapolated Volume
- SVC: SVC, ERV, IRV, TV, EC
- MVV: MVV, FB, TV56 Presentation Flow volume loop
MVV: MVV, FB, TV
Measurement values table59 Measuring Range Flow: 0 to ± 14 L/s
Volume: 0 to ± 12 L62 Measuring Method Differential pressure method 65 Prediction Equation Morris-Polgar, ECCS-Quanjer, Knudson-ITS, Pereira, Korea CJK 66 Sample Rate 200 samples/sec 67 Flow Impedance < 0.2 mbar s/l at 12 l/s 68 Measuring Accuracy Complies with ATS (American Thoracic Society) 69 Environment Ambient temperature: 15 to 40°C (59 to 104°F)
Relative humidity: 10 to 90% (non-condensing)
Atmospheric pressure: 700 to 1060 hPa* Specifications can be changed without prior notification.
- Accessories
-
Item Code Item Description wdt_ID Item Image Item Code Item Description Buy Now 63 ECG-BAT-B ECG rechargeable battery (Li-ion) for Cardio7 with serial number starting with T9 Buy Now 65 USB-WIFI24 USB WiFi dongle (2.4 GHz) Buy Now 66 PC-A (H) Hospital grade power cable Buy Now 67 ECG-CART ECG cart for CardioCare 2000 and Cardio7 (hanger not included, must be purchased separately) Buy Now 71 ECG-STYLUS ECG touch screen stylus pen (for Cardio7 only) Buy Now 72 SPM-300(U) Spirometer – requires Cardio7 ECG unit.
Includes: one sensor, one handle dock, one nose clip, one diagnosis guide, one operation manual, and 100 mouthpieces – Does Not include calibration syringe.Contact Sales 73 SPM-MP SmarTube (disposable mouthpiece - 100/box) (no warranty) Buy Now 74 SPM-CS 3L calibration syringe (90-day warranty) Buy Now - Downloads